Passa al contenuto principale
Filtro
Suggerimento
Nuovo
Coolenvi™ Montaggio SET 230 V Cavo di alimentazione e fusibile monofase
Coolenvi™ Montaggio SET 230 V Cavo di alimentazione e fusibile monofase
Item - Connection Length: 5m | Task - E&IC : E | 1 Phase | 16 A | no Surge Arrester
This installation set includes a coordinated material package for the creation of electrical supply lines and protection. Suitable for air conditioning systems, split units, control cabinets or other technical systems with a single-phase 230-volt power supply. The installation SET has been configured for TT systems. A service socket for outdoor maintenance work is included in the set. The set provides all essential installation components typically required for a standards-compliant electrical supply line and device protection. The installation itself is not part of this offer. Installation set variants Variant 1 – Basic installation Material package for a standard installation of electrical supply lines including the necessary protection and maintenance switch. Required space in the existing distribution board: 5 module units for single-phase circuits (230 V) 10 module units in mixed three-phase distribution boards (400 V) Main terminal block with free outgoing capacity for L, N, PE Material package contains up to 16A: DE-HS1003 - Installation cable NYY 3x2.5qmm / electrical supply line DE-UN1000 - H07VK flexible conductor cable black 4 qmm DE-UN1100 - H07VK flexible conductor cable blue 4 qmm DE-UN1200 - H07VK flexible conductor cable green-yellow 4 qmm Various small materials for distribution without terminal block DE-HAGMCB03KA1P16A - miniature circuit breaker 16A (MCB) Material package contains for 20 to 25A: DE-HS1004 - Installation cable NYY 3x4qmm / electrical supply line DE-UN1001 - H07VK flexible conductor cable black 6 qmm DE-UN1101 - H07VK flexible conductor cable blue 6 qmm DE-UN1201 - H07VK flexible conductor cable green-yellow 6 qmm Various small materials for distribution without terminal block DE-HAGMCB06KA1P025A - miniature circuit breaker 25A (MCB) Material package contains for 32A: DE-HS1005 - Installation cable NYY 3x6qmm / electrical supply line DE-UN1002 - H07VK flexible conductor cable black 10 qmm DE-UN1102 - H07VK flexible conductor cable blue 10 qmm DE-UN1202 - H07VK flexible conductor cable green-yellow 10 qmm Various small materials for distribution without terminal block DE-HAGMCB06KA1P032A - miniature circuit breaker 32A (MCB) Material package contains for 40A: DE-HS1006 - Installation cable NYY 3x10qmm / electrical supply line DE-UN1003 - H07VK flexible conductor cable black 16 qmm DE-UN1103 - H07VK flexible conductor cable blue 16 qmm DE-UN1203 - H07VK flexible conductor cable green-yellow 16 qmm Various small materials for distribution without terminal block 0000 - miniature circuit breaker 40A (MCB) Material package contains for 50A: DE-HS1007 - Installation cable NYY 3x16qmm / electrical supply line 0000 - H07VK flexible conductor cable black 25 qmm 0000 - H07VK flexible conductor cable blue 25 qmm 0000 - H07VK flexible conductor cable green-yellow 25 qmm Various small materials for distribution without terminal block 0000 - miniature circuit breaker 50A (MCB) Material package contains for 63A: 0000 - Installation cable NYY 3x25qmm / electrical supply line 0000 - H07VK flexible conductor cable black 35 qmm 0000 - H07VK flexible conductor cable green-yellow 35 qmm 0000 - H07VK flexible conductor cable blue 35 qmm Various small materials for distribution without terminal block 0000 - miniature circuit breaker 63A (MCB) Material package included in all variants: DE-HAGMCB03KA1P16A - miniature circuit breaker 16A (MCB) DE-HAGCD264J - residual current device (RCD) DE-HAGKB263A - Bus Bar 1 pole DK-KG32T20340KL51V - maintenance and repair switch for outdoor units DE-MERT23018029 maintenance / service socket outdoor DK-HAGVZ025M - cable glands DE-WU097364040 - cable protection / cable routing channel with mounting material DE-WU05021413.2 - cable ties fastening material Variant 2 – Installation with 2-pole surge protection Extended material package with additional protection against grid disturbances and voltage spikes. Required space in the existing distribution board: 7 module units for single-phase circuits (230 V) in three-phase distribution boards 12 module units in mixed three-phase distribution boards (400 V) Main terminal block with free outgoing capacity for L, N, PE Material package additionally contains: DE-DEHSPD014-900454 - surge protection (SPD) for network and device protection 2-pole Installation components for integration of surge protection Variant 3 – Installation with 4-pole surge protection Extended material package with additional protection against grid disturbances and voltage spikes. Typical space requirement in the existing distribution board: 12 module units for single-phase circuits (230 V) in three-phase distribution boards 12 module units in mixed three-phase distribution boards (400 V) Main terminal block with free outgoing capacity for L1, L2, L3, N, PE Material package additionally contains: DE-DEHSPD016-952310 - surge protection (SPD) for network and device protection 4-pole Installation components for integration of surge protection Notes on space requirements and installation Before installing this installation set, it must be checked whether the existing distribution cabinet has sufficient space and capacity reserves for the required protection components. The specified module units (TE) serve as a guideline for estimating the required installation space. The installation set is designed for use in TN and TT systems; system-specific connection and installation requirements must be observed. If the available space or capacity reserve is insufficient, installation of a separate small distribution board or sub-distribution board may be required. This material is not included in this installation set. Installation of the included components may only be carried out by qualified electrical professionals in accordance with the applicable electrical safety requirements (5-rule safety principle). The scope of delivery does not include technical fire protection. If required, it must be planned, ordered and installed separately. Typical applications Control cabinets Split air conditioning systems Small heat pumps Ventilation units Technical systems with 230-volt supply NOTE: The product image is not binding and does not represent a claim to the contents of the set. This item is manufactured according to your specifications. Therefore, you have no right of withdrawal and no Coolenvi return policy applies.

223,21 €*
Suggerimento
Nuovo
Coolenvi™ Montaggio SET 400 V Cavo di alimentazione e fusibile 3 fase
Coolenvi™ Montaggio SET 400 V Cavo di alimentazione e fusibile 3 fase
Item - Connection Length: 10m | Task - E&IC : E | 3 Phase | 16 A | no Surge Arrester
Questo set di montaggio include una composizione di materiali coordinata per la realizzazione di linee elettriche e protezioni. Adatto per condizionatori, unità split, quadri elettrici o altre installazioni tecniche con alimentazione 3-fase a 400 Volt. Una presa di servizio per manutenzione esterna è inclusa nel set. Il set fornisce tutti i componenti di installazione essenziali normalmente richiesti per una linea elettrica conforme e protezione dei dispositivi. L’installazione stessa non è inclusa in questa offerta. Varianti del set di montaggio Variante 1 – Installazione base Composizione dei materiali per un’installazione standard di linee elettriche inclusa protezione necessaria e interruttore di manutenzione. Spazio tipico richiesto nel quadro esistente: 2 TE per uscite monofase (230 V) 5 TE per uscite trifase (400 V) in quadri misti Il pacchetto materiali include: [ART-XXXX] Cavi di installazione / linee di alimentazione elettrica [ART-XXXX] Interruttore automatico (LS) [ART-XXXX] Interruttore differenziale (FI/RCD) [ART-XXXX] Interruttore di manutenzione / servizio per unità esterne [ART-XXXX] Presa di servizio / manutenzione esterna [ART-XXXX] Pressacavi [ART-XXXX] Protezione cavi / materiale di installazione Variante 2 – Installazione con protezione da sovratensione 2 poli Composizione dei materiali estesa con protezione aggiuntiva contro disturbi di rete e picchi di tensione. Spazio tipico richiesto nel quadro esistente: 7 TE per uscite monofase (230 V) in quadri trifase 10 TE per uscite trifase (400 V) Il pacchetto materiali include inoltre: [ART-XXXX] Protezione da sovratensione (SPD) 2 poli per rete e dispositivi [ART-XXXX] Componenti di installazione per integrazione della protezione da sovratensione Variante 3 – Installazione con protezione da sovratensione 4 poli Composizione dei materiali estesa con protezione aggiuntiva contro disturbi di rete e picchi di tensione. Spazio tipico richiesto nel quadro esistente: 7 TE per uscite monofase (230 V) in quadri trifase 10 TE per uscite trifase (400 V) Il pacchetto materiali include inoltre: [ART-XXXX] Protezione da sovratensione (SPD) 4 poli per rete e dispositivi [ART-XXXX] Componenti di installazione per integrazione della protezione da sovratensione Note su spazio e installazione Per utilizzare questo set di montaggio, è necessario che nel quadro esistente ci sia spazio sufficiente per i componenti di protezione richiesti. Le indicazioni delle unità modulari (TE) servono come orientamento per valutare lo spazio necessario. Se lo spazio disponibile non è sufficiente, potrebbe essere necessaria l’installazione di un quadro secondario o di sottoquadri. Questo materiale non fa parte del set di montaggio. L’installazione dei componenti inclusi deve essere effettuata esclusivamente da personale elettrico qualificato, rispettando le norme di sicurezza elettrica vigenti. Il set non include protezione antincendio tecnica. Se necessario, deve essere pianificata e installata separatamente. Applicazioni tipiche Quadri elettrici Climatizzatori split Piccole pompe di calore Sistemi di ventilazione Impianti tecnici con alimentazione a 230 Volt

Varianti da 0,00 €*
354,08 €*